Permanganate Index Water Quality Online Analyzer
● 7 inch LCD touch screen
● Can store more than 100000 groups of data
● With calibration, status, alarm record function
● With self-diagnosis, lack of liquid alarm function
● With manual, interval, whole point and other measurement modes
● After power failure, the measurement function will be activated when the caller comes in.
● The number of ranges and the range can be set.
● Support multi-point calibration function
● Automatic calibration liquid verification, support the setting of automatic calibration liquid verification interval time
● Can be automatically calibrated, support for setting the calibration interval time
● Receive remote control commands from the management platform
Specifications
Determination principle: Add a certain amount of sulfuric acid and excess potassium permanganate to the water sample to be tested, oxidize certain organic matter and inorganic reducing substances in the sample at high temperature, add excess sodium oxalate solution to reduce the remaining potassium permanganate, then use potassium permanganate to back-titrate the remaining sodium oxalate, and calculate the permanganate index in the water sample.
Additional information
| Measurement method | Potassium permanganate oxidation titration |
|---|---|
| Measuring range | 0-10/20/100mg/L; expandable |
| Measuring cycle | Configurable |
| Lower limit of quantification | ≤0.5mg/L |
| Indication error | ±5% |
| Repeatability | ≤5% |
| Zero drift | ±5% |
| Range drift | ±5% |
| Digital Input | 2 channel switch |
| Analog Output | 1 channel 4~20mA |
| Digital Communications | RS232 / RS485 |
| Operating temperature | 5℃~40℃ |
| power supply | AC 100~240V ;50/60Hz |
| power | 80W |
| size | 800mm x 400mm x 330mm |
| weight | 25kg (without reagents) |